EV-Tronix carries LS Electric Circuit Breakers. Miniature Circuit Breakers (MCBs) are placed directly above the load and are designed to protect final loads. They are ideal for protection of circuits in industrial, commercial, and residential sectors, and ensures the following functions: protection against short-circuit and overload currents, isolation, and protection against indirect contact. LS Electric Molded Case Circuit Breakers (MCCB) are designed to protect low voltage electrical systems from overloads and short circuits.
A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by overcurrent or short circuit by automatically interrupting the flow of electricity when a fault is detected.
- Fixed Thermal, Fixed Magnet
- 25A Current Rating, 3 Number of Poles
- Lugs Line/Load Side
- Thermal-Magnetic 40 A through 150 A
- Suitable for Branch Circuit Protection
- UL489 Listed for use on UL508 Control Panels
- Shunt Trip, Undervoltage Release and Other Accessories available
- Line and Load Lug Terminals included on All MCCBs
- Toggle Handle provides Three Positions (On/Off and Tripped)
- HACR (Heating, Air Conditioning and Refrigeration Rated)
- Auxiliary Switch, Alarm Switch, Shunt Trip and Undervoltage
- Release can be installed in the field
- Door-Mounted or Flange-Mounted, Flex Shaft Operating Handles available
- All Frame Sizes Suitable For Reverse-Feed Applications
- All Breakers include Mounting Hardware
- UL489 MCCB, File E231289
- UL489 Circuit-Breaker Accessories, File E223241
- Fixed Thermal, Fixed Magnet
- 60A Current Rating, 3 Number of Poles
- Lugs Line/Load Side
- Thermal-Magnetic 40 A through 150 A
- Suitable for Branch Circuit Protection
- UL489 Listed for use on UL508 Control Panels
- Shunt Trip, Undervoltage Release and Other Accessories available
- Line and Load Lug Terminals included on All MCCBs
- Toggle Handle provides Three Positions (On/Off and Tripped)
- HACR (Heating, Air Conditioning and Refrigeration Rated)
- Auxiliary Switch, Alarm Switch, Shunt Trip and Undervoltage
- Release can be installed in the field
- Door-Mounted or Flange-Mounted, Flex Shaft Operating Handles available
- All Frame Sizes Suitable For Reverse-Feed Applications
- All Breakers include Mounting Hardware
- UL489 MCCB, File E231289
- UL489 Circuit-Breaker Accessories, File E223241
- Fixed Thermal, Fixed Magnet
- 80A Current Rating, 3 Number of Poles
- Lugs Line/Load Side
- Thermal-Magnetic 40 A through 150 A
- Suitable for Branch Circuit Protection
- UL489 Listed for use on UL508 Control Panels
- Shunt Trip, Undervoltage Release and Other Accessories available
- Line and Load Lug Terminals included on All MCCBs
- Toggle Handle provides Three Positions (On/Off and Tripped)
- HACR (Heating, Air Conditioning and Refrigeration Rated)
- Auxiliary Switch, Alarm Switch, Shunt Trip and Undervoltage
- Release can be installed in the field
- Door-Mounted or Flange-Mounted, Flex Shaft Operating Handles available
- All Frame Sizes Suitable For Reverse-Feed Applications
- All Breakers include Mounting Hardware
- UL489 MCCB, File E231289
- UL489 Circuit-Breaker Accessories, File E223241
- Fixed Thermal, Fixed Magnet
- 125A Current Rating, 3 Number of Poles
- Lugs Line/Load Side
- Thermal-Magnetic 40 A through 150 A
- Suitable for Branch Circuit Protection
- UL489 Listed for use on UL508 Control Panels
- Shunt Trip, Undervoltage Release and Other Accessories available
- Line and Load Lug Terminals included on All MCCBs
- Toggle Handle provides Three Positions (On/Off and Tripped)
- HACR (Heating, Air Conditioning and Refrigeration Rated)
- Auxiliary Switch, Alarm Switch, Shunt Trip and Undervoltage
- Release can be installed in the field
- Door-Mounted or Flange-Mounted, Flex Shaft Operating Handles available
- All Frame Sizes Suitable For Reverse-Feed Applications
- All Breakers include Mounting Hardware
- UL489 MCCB, File E231289
- UL489 Circuit-Breaker Accessories, File E223241
- Auxiliary Contact, AX, for UTS150~UTS600
- Contacts: 1 NO/NC closed when circuit "off"
- Amp Rating: 5 Amps at 125 VAC
- Screw Terminals